| Test Port | |
| Frequency Range [GHz] | 140 to 220 |
| Port Type | WM-1295 (UG387/U flange compatible) |
| Output Power [dBm (typ.)] | 140 to 145 GHz > -4 dBm (n.trc.), typ. 0 dBm 145 to 220 GHz > -2 dBm (n.trc.), typ. +2 dBm |
| Output Power Attenuation [dB] | 0 to 40 |
| Input Power Damage Level [dBm] | +20 |
| Stability (Magnitude [dB] / Phase [°] (typ.) ) | typ. < 0.3 dB and typ.< 4° |
| Source Input (RF IN) | |
| Frequency Range [GHz] | 11.66 to 18.33 |
| Port Type | 2.92 mm, female |
| Input Power Range [dBm] | -15 to +10 |
| Local Oscillator Input (LO IN) | |
| Frequency Range [GHz] | 11.64 to 18.31 |
| Port Type | SMA, female |
| Input Power Range [dBm] | +5 to +10 |
| Measurement Output (MEAS OUT) | |
| Frequency Range [MHz] | 5 to 2000 |
| Port Type | SMA, female |
| Reference Output (REF OUT) | |
| Frequency Range [MHz] | 5 to 2000 |
| Port Type | SMA, female |
| System Characteristics | |
| Source match (without system error correction) | > 25 dB (n.trc.)1 |
| Directivity (without system error correction) | > 25 dB (n.trc.)1 |
| Dynamic Range [dB] | > 100, typ. 115 |
Dynamic range is defined as the difference between the data trace of the transmission magnitude with maximum test port output power and both
test ports through-connected on the one hand and the RMS value of the data trace of the transmission magnitude produced by noise and crosstalk
with test ports short-circuited on the other. The specification is valid without system error correction and at 10Hz measurement bandwidth. The
dynamic range can be increased by using a measurement bandwidth of 1Hz.
1 Without consideration of measurement uncertainty.